2021 International Residential Code®
By International Code Council (ICC)
About your course materials
This comprehensive code comprises all building, plumbing, mechanical, fuel gas and electrical requirements for one- and two-family dwellings and townhouses up to three stories. The 2021 IRC® contains many important changes such as: Braced wall lines must be placed on a physical wall or placed between multiple walls. The rated separation for two-family dwellings is 1 hour whether or not a lot line exists between units. Emergency escape and rescue openings require a clear 36-inch-wide path to a public way. An engineered design is required for storm shelters. A habitable attic is limited to one-half the area of the story below and the dwelling requires sprinklers. Updated Wind Speed maps match IBC and ASCE 7 maps. Deck design now considers snow load, tributary area for footing and post height, and guard details. Specific requirements for deck guardrails were added. Component and cladding wind pressures in Table R301.2(2) are updated for new design wind speeds and hip or gable roof profiles. Minimum footing size tables are revised to more accurately reflect current practice. Cripple wall requirements apply only to exterior cripple walls. New appendices for cob construction and 3D printed construction are added. A 30 percent reduction of airflow is permitted for balanced ventilation systems. Commercial gas cooking appliances are prohibited. The head pressure for a water test of DWV systems increased to 10 feet. Air vacuum testing is now permitted for plastic piping DWV systems. Section P2904 for dwelling sprinklers is expanded to more closely align with NFPA 13D. An emergency service disconnect is required in a readily accessible outdoor location. A surge-protective device (SPD) is now required at the service panel. The number of receptacle outlets required for peninsular and island countertops in kitchens is determined by the area of the countertop surface.
Frequently asked questions
How do I enroll in or join my course?
How do I redeem an access code, or what if my code isn't working?
Why can't I access my course?
Where can I find my eBook or textbook?
What if I don't have access to my course materials yet?
About this product
This comprehensive code comprises all building, plumbing, mechanical, fuel gas and electrical requirements for one- and two-family dwellings and townhouses up to three stories. The 2021 IRC® contains many important changes such as: Braced wall lines must be placed on a physical wall or placed between multiple walls. The rated separation for two-family dwellings is 1 hour whether or not a lot line exists between units. Emergency escape and rescue openings require a clear 36-inch-wide path to a public way. An engineered design is required for storm shelters. A habitable attic is limited to one-half the area of the story below and the dwelling requires sprinklers. Updated Wind Speed maps match IBC and ASCE 7 maps. Deck design now considers snow load, tributary area for footing and post height, and guard details. Specific requirements for deck guardrails were added. Component and cladding wind pressures in Table R301.2(2) are updated for new design wind speeds and hip or gable roof profiles. Minimum footing size tables are revised to more accurately reflect current practice. Cripple wall requirements apply only to exterior cripple walls. New appendices for cob construction and 3D printed construction are added. A 30 percent reduction of airflow is permitted for balanced ventilation systems. Commercial gas cooking appliances are prohibited. The head pressure for a water test of DWV systems increased to 10 feet. Air vacuum testing is now permitted for plastic piping DWV systems. Section P2904 for dwelling sprinklers is expanded to more closely align with NFPA 13D. An emergency service disconnect is required in a readily accessible outdoor location. A surge-protective device (SPD) is now required at the service panel. The number of receptacle outlets required for peninsular and island countertops in kitchens is determined by the area of the countertop surface.
Table of contents
- 1. Scope and Administration
- 2. Definitions
- 3. Building Planning
- 4. Foundations
- 5. Floors
- 6. Wall Construction
- 7. Wall Covering
- 8. Roof-Ceiling Construction
- 9. Roof Assemblies
- 10. Chimneys and Fireplaces
- 11. Energy Efficiency
- 12. Mechanical Administration
- 13. General Mechanical System Requirements
- 14. Heating and Cooling Equipment and Appliances
- 15. Exhaust Systems
- 16. Duct Systems
- 17. Combustion Air
- 18. Chimneys and Vents
- 19. Special Appliances, Equipment and System
- 20. Boilers and Water Heaters
- 21. Hydronic Piping
- 22. Special Piping and Storage Systems
- 23. Solar Thermal Energy Systems
- 24. Fuel Gas
- 25. Plumbing Administration
- 26. General Plumbing Requirements
- 27. Plumbing Fixture
- 28. Water Heaters
- 29. Water Supply and Distribution
- 30. Sanitary Drainage
- 31. Vents
- 32. Traps
- 33. Storm Drainage
- 34. General Requirements
- 35. Electrical Definitions
- 36. Services
- 37. Branch Circuit and Feeder Requirements
- 38. Wiring Methods
- 39. Power and Lighting Distribution
- 40. Devices and Luminaires
- 41. Appliance Installation
- 42. Swimming Pools
- 43. Class 2 Remote-Control, Signaling and Power-Limited Circuits
- 44. Referenced Standards
- 45. Appendix AA: Siting and Capacities of Gas Piping
- 46. Appendix AB: Sizing of Venting Systems Serving Appliances Equipped with Draft Hoods, Category I Appliances and Appliances Listed for Use with Type B Vents
- 47. Appendix AC: Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems
- 48. Appendix AD: Recommended Procedure for Safety Inspection of Existing Appliance Installation
- 49. Appendix AE: Manufactured Housing Used as Dwellings
- 50. Appendix AF: Radon Control Methods
- 51. Appendix AG: Piping Standards for Various Applications
- 52. Appendix AH: Patio Covers
- 53. Appendix AI: Private Sewage Disposal
- 54. Appendix AJ: Existing Buildings and Structures
- 55. Appendix AK: Sound Transmission
- 56. Appendix AL: Permit Fees
- 57. Appendix AM: Home Day Care- R-3 Occupancy
- 58. Appendix AN: Venting Methods
- 59. Appendix AO: Automatic Vehicular Gates
- 60. Appendix AP: Sizing of Water Piping System
- 61. Appendix AQ: Tiny Houses
- 62. Appendix AR: Light Straw-Clay Construction
- 63. Appendix AS: Strawbale Construction
- 64. Appendix AT: Solar Ready Provisions-Detached One and Two-Family Dwellings and Townhouses
- 65. Appendix AU: COB Construction (Monolithic Adobe)
- 66. Appendix AV: Board of Appeals
- 67. Appendix AW: 3D-Printed Building Construction
- Index
- Resource A: Recommended Practices for Remote Virtual Inspections (RVI)
Resources
Instructor resources for this title can include manuals, test banks, educator guides, multimedia and companion sites. Sign in to see what is available.
Pricing and formats
Paperback
Loose-leaf

Still need support?




