2021 International Building Code®, Loose-leaf Version
By International Code Council (ICC)
About your course materials
This code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2021 IBC® contains many important changes such as:
Puzzle rooms (escape rooms) are now defined and regulated as special amusement areas, requiring compliance with Section 411 and special means of egress requirements. For the purposes of determining the allowable number of control areas in a building, each portion separated by one or more fire walls is now considered as a separate building. In Group E occupancies, enhanced classroom acoustics in compliance with ICC A117.1 are to be provided in all classrooms having of volume of 20,000 cubic feet or less. The requirements for metal composite materials and systems (MCM) installed on the exterior walls of Types I, II, III and IV construction were simplified and sprinkler allowances were deleted.
The use of intermodal shipping containers as buildings is now specifically addressed through provisions intended to supplement existing applicable IBC requirements. Automatic sprinkler protection is now required in Group S-2 open parking garages where any fire area exceeds 48,000 square feet. The 2017 edition of ICC A117.1 was adopted. Parapets of a minimum height are now required for aggregate-surfaced roofs to prevent blow-off. Mixed occupancy buildings with assembly spaces are placed in Risk Category III when the total public assembly occupant load is greater than 2500 people. The 2021 IBC snow map is updated to match ASCE 7-16 snow maps by adding a reference to ASCE 7 snow tables in states with large case study areas. Secondary rain loads are updated to be consistent with ASCE 7.
Frequently asked questions
How do I enroll in or join my course?
How do I redeem an access code, or what if my code isn't working?
Why can't I access my course?
Where can I find my eBook or textbook?
What if I don't have access to my course materials yet?
About this product
This code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2021 IBC® contains many important changes such as:
Puzzle rooms (escape rooms) are now defined and regulated as special amusement areas, requiring compliance with Section 411 and special means of egress requirements. For the purposes of determining the allowable number of control areas in a building, each portion separated by one or more fire walls is now considered as a separate building. In Group E occupancies, enhanced classroom acoustics in compliance with ICC A117.1 are to be provided in all classrooms having of volume of 20,000 cubic feet or less. The requirements for metal composite materials and systems (MCM) installed on the exterior walls of Types I, II, III and IV construction were simplified and sprinkler allowances were deleted.
The use of intermodal shipping containers as buildings is now specifically addressed through provisions intended to supplement existing applicable IBC requirements. Automatic sprinkler protection is now required in Group S-2 open parking garages where any fire area exceeds 48,000 square feet. The 2017 edition of ICC A117.1 was adopted. Parapets of a minimum height are now required for aggregate-surfaced roofs to prevent blow-off. Mixed occupancy buildings with assembly spaces are placed in Risk Category III when the total public assembly occupant load is greater than 2500 people. The 2021 IBC snow map is updated to match ASCE 7-16 snow maps by adding a reference to ASCE 7 snow tables in states with large case study areas. Secondary rain loads are updated to be consistent with ASCE 7.
Table of contents
- Chapter 1. Scope and Administration
- Chapter 2. Definitions
- Chapter 3. Occupancy Classification and Use
- Chapter 4. Special Detailed Requirements Based on Occupancy and Use
- Chapter 5. General Building Heights and Areas
- Chapter 6. Types of Construction
- Chapter 7. Fire and Smoke Protection Features
- Chapter 8. Interior Finishes
- Chapter 9. Fire Protection and Life Safety Systems
- Chapter 10. Means of Egress
- Chapter 11. Accessibility
- Chapter 12. Interior Environment
- Chapter 13. Energy Efficiency
- Chapter 14. Exterior Walls
- Chapter 15. Roof Assemblies and Rooftop Structures
- Chapter 16. Structural Design
- Chapter 17. Special Inspections and Tests
- Chapter 18. Soils and Foundations
- Chapter 19. Concrete
- Chapter 20. Aluminum
- Chapter 21. Masonry
- Chapter 22. Steel
- Chapter 23. Wood
- Chapter 24. Glass and Glazing
- Chapter 25. Gypsum Board, Gypsum Panel Products, and Plaster
- Chapter 26. Plastic
- Chapter 27. Electrical
- Chapter 28. Mechanical Systems
- Chapter 29. Plumbing Systems
- Chapter 30. Elevators and Conveying Systems
- Chapter 31. Special Construction
- Chapter 32. Encroachment Into the Public Right-of-Way
- Chapter 33. Safeguards During Construction
- Chapter 34. Reserved
- Chapter 35. Referenced Standards
- Appendix A. Employee Qualifications
- Appendix B. Board of Appeals
- Appendix C. Group U – Agricultural Buildings
- Appendix D. Fire Districts
- Appendix E. Supplementary Accessibility Requirements
- Appendix F. Rodentproofing
- Appendix G. Flood-Resistant Construction
- Appendix H. Signs
- Appendix I. Patio Covers
- Appendix J. Grading
- Appendix K. Administrative Provisions
- Appendix L. Earthquake Recording Instrumentation
- Appendix M. Tsunami-Generated Flood Hazards
- Appendix N. Replicable Buildings
- Appendix O. Performance-Based Application
- Resource A. Recommended Practices for Remote Virtual Inspections (RVI)
Resources
Instructor resources for this title can include manuals, test banks, educator guides, multimedia and companion sites. Sign in to see what is available.
Pricing and formats
Loose-leaf

Still need support?




